Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
Using inductively coupled plasma-mass spectrometry for calibration transfer between environmental CRMs
1Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899-8391, USA. turk@nist.gov
This study demonstrates a high-performance method for calibrating environmental reference materials using certified reference materials (CRMs). The technique yields measurement uncertainties comparable to the CRM
Area of Science:
- Environmental Science
- Analytical Chemistry
- Geochemistry
Background:
- Accurate elemental analysis of environmental samples is crucial for monitoring and research.
- Certified Reference Materials (CRMs) are essential for calibrating analytical instruments.
- Existing calibration methods may have limitations in achieving low measurement uncertainties.
Purpose of the Study:
- To develop and validate a high-performance methodology for multielement analysis of environmental reference materials.
- To establish a robust calibration transfer technique using CRMs.
- To propose novel applications for this calibration transfer method.
Main Methods:
- Utilized inductively coupled plasma-mass spectrometry (ICP-MS) for multielement analysis.
- Employed existing CRMs as calibration standards for the ICP-MS method.
- Implemented a high-performance analytical methodology to minimize comparison measurement uncertainties.
Main Results:
- Achieved comparison measurement uncertainties significantly lower than the certified values of the calibration CRMs.
- Determined values exhibited uncertainties nearly equivalent to those of the calibration CRMs.
- Successfully analyzed various environmental reference materials, including river sediment and coal samples.
Conclusions:
- The developed methodology offers a reliable and accurate approach for calibrating environmental reference materials.
- This calibration transfer technique enables precise re-certification of CRMs and establishes traceability between different CRMs.
- The method is effective for demonstrating the equivalence of CRMs, enhancing data comparability in environmental studies.
Related Concept Videos
High-Resolution Mass Spectrometry (HRMS)
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab