Quantification of [(18)F]FDG uptake in the normal liver using dynamic PET: impact and modeling of the dual hepatic blood supply
Related Experiment Video
Updated: Oct 5, 2026

Determining Glucose Metabolism Kinetics Using 18F-FDG Micro-PET/CT
Published on: May 2, 2017
G Brix1, S I Ziegler, M E Bellemann
1Research Program Radiological Diagnostics and Therapy, German Cancer Research Center, Heidelberg, Germany.
Unlabelled:
For quantification of hepatic [(18)F]FDG uptake, the dual blood supply to the liver must be considered. In contrast to the arterial input, however, the portal venous blood supply to the liver cannot be monitored directly by PET because of the inaccessibility of the portal vein on PET scans. In this study, we investigated whether the dual hepatic input can be predicted from the measurable arterial input. Moreover, we assessed the effect of different input models on the rate constants of the standard 3-compartment model describing regional uptake of FDG.
Methods:
Dynamic FDG PET scanning was performed on 5 foxhounds. Activity concentrations in blood from the aorta and the portal vein were measured simultaneously using external circuits. After image reconstruction, time--activity courses were determined from the aorta and the liver. The venous input was approximated by convolving the arterial input with a notional system function describing the dispersion of the arterial input on its way through the gastrointestinal tract. On the basis of these data, 5 different hepatic input models, which pertain to a single-input as well as a dual-input scenario, were statistically compared with regard to the adequacy of the model fits to liver data and to differences in the estimated rate constants.
Results:
Portal venous input to the liver could be approximated by convolving the arterial input function with a system function. From this function, a mean transit time of 25 s was computed for FDG to pass through the gastrointestinal tract. According to the statistical analysis, dual-input models were superior to their single-input counterparts. However, differences in the rate constants estimated for the 5 input models were in the same order as interindividual variations within the different model groups. For the dephosphorylation rate constant, a consistent value of 0.05 +/- 0.01 min(-1) was found.
Conclusion:
Dual-input models proved to be superior to single-input models with respect to the adequacy of FDG model fits to normal liver data. However, the hepatic blood supply may be approximated by the arterial input function as well, especially for the evaluation of liver lesions mainly fed by the hepatic artery.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...