Related Experiment Video
Updated: Aug 19, 2026

Determining the Chemical Composition of Corrosion Inhibitor/Metal Interfaces with XPS: Minimizing Post Immersion Oxidation
Published on: March 15, 2017
Estimation of the atmospheric corrosion on metal containers in industrial waste disposal
M Baklouti1, N Midoux, F Mazaudier
1Laboratoire des Sciences du Génie Chimique, CNRS-ENSIC, 1 rue Grandville, BP 451, F-54001 Cedex, Nancy, France. baklouti@ensic.u-nancy.fr
Abstract:
Solid industrial waste are often stored in metal containers filled with concrete, and placed in well-aerated warehouses. Depending on meteorological conditions, atmospheric corrosion can induce severe material damages to the metal casing, and this damage has to be predicted to achieve safe storage. This work provides a first estimation of the corrosivity of the local atmosphere adjacent to the walls of the container through a realistic modeling of heat transfer phenomena which was developed for this purpose. Subsequent simulations of condensation/evaporation of the water vapor in the atmosphere were carried out. Atmospheric corrosion rates and material losses are easily deduced. For handling realistic data and comparison, two different meteorological contexts were chosen: (1) an oceanic and damp atmosphere and (2) a drier storage location. Some conclusions were also made for the storage configuration in order to reduce the extent of corrosion phenomena.
More Related Videos
Related Concept Videos
Corrosion
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Microbial Corrosion