Related Experiment Video
Updated: Aug 1, 2026

Environmentally-controlled Microtensile Testing of Mechanically-adaptive Polymer Nanocomposites for ex vivo Characterization
Published on: August 20, 2013
Effect of light power density on development of elastic modulus of a model light-activated composite during
1Department of Biomaterials and Biomechanics, Oregon Health Sciences University, Portland 97201, USA. sakaguch@ohsu.edu
Purpose:
Elastic modulus development during polymerization of a composite is a measure of the polymerization maturity and the restoration's ability to transfer stress to enamel and dentin. The characteristics of elastic modulus development in real time during cure are largely unknown. The purpose of this study was to evaluate the effect of light power density and total energy density on the early development of elastic modulus for a light-activated composite.
Methods:
Cylindrical specimens of a model hybrid composite were tested in flexure in a dynamic mechanical analyzer (DMA). Specimens were light-activated (Variable Intensity Polymerizer, Bisco, Itasca, Illinois) for 60 seconds. Elastic modulus was measured continuously for 5 minutes from the start of light activation. Development of elastic modulus was assessed for six different light power densities and two reduced power density levels given at longer exposure duration to provide similar energy density values. One-way analysis of variance with Tukey's post hoc comparison test was used to evaluate significant differences of elastic modulus at p = .05.
Results:
The rates of elastic modulus development and final moduli were dependent on the light power density applied. Composite specimens cured by equivalent energy densities using short times and high power density or long times and low power density produced equivalent elastic moduli. Elastic moduli for emitted power densities between 400 and 600 mW/cm2 (160-260 mW/cm2 measured at the specimen surface) were not significantly different (p > .05).
Conclusions:
Light power densities greater than 160 mW/cm2 measured at the specimen surface resulted in elastic moduli that were not significantly different. Equivalent energy densities produced comparable elastic moduli.
Related Concept Videos
Strain and Elastic Modulus
Polymer Classification: Architecture
Hooke's Law
Plastic Behavior
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...