Determination of pesticides in drinking water by micellar electrokinetic capillary chromatography
1Centre of Applied Spectroscopy and Analytical Sciences, Department of Chemistry, The University of Hong Kong, Hong Kong SAR, China. ysfung@hkucc.hku.hk
Abstract:
A new analytical procedure using a two-step sample preconcentration (solid-phase extraction (SPE) and field-amplified sample stacking) prior to separation by micellar electrokinetic capillary chromatography was developed for the determination of 14 pesticides such as aldicarb, carbofuran, isoproturon, chlorotoluron, metolachlor, mecoprop, dichlorprop, MCPA, 2,4-D, methoxychlor, TDE, DDT, dieldrin, and DDE in drinking water. Good recoveries of pesticides were obtained using SPE with sample pH adjusted to 2-3. Field-amplified sample stacking was found to give enrichment factors up to 30-fold preconcentration of various pesticides under reversed polarity at -2 kV for 50 s. The optimized background electrolyte (BGE) consisted of 50 mM sodium dodecyl sulfate (SDS), 10 mM borate buffer, 15 mM beta-cyclodextrin (beta-CD), and 22% acetonitrile at pH 9.6, running was under 25 kV and detection at 202 nm. Good linearity was obtained for all pesticides with detection limits down to 0.04-0.46 ng/mL and a working range of 0.1-40 ng/mL. The repeatabilities of migration time and peak area were satisfactory with relative standard deviations (RSDs) between 0.66 and 13.6% and 4.1 and 28%, respectively. All pesticides except dieldrin were found to be detected at concentrations at least tenfold lower than the World Health Organization (WHO) guideline values. The analytical procedure developed offers an economic method for fast screening of multiple pesticide residues in drinking water for health protection. It had been applied to determine carbofuran and MCPA in agricultural run-off water samples, giving satisfactory repeatabilities of 10 and 12%, respectively, with n=5 for the determination of pesticides in contaminated water samples.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Electrophoresis: Overview
There...