Related Experiment Video
Updated: Oct 4, 2026

Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Regulation of electroosmotic flow and electrophoretic mobility of proteins for concentration without desalting
Abstract:
Proteins were concentrated and separated in 0.6% poly(ethylene oxide) (PEO) solution using a capillary filled with Tris-borate (TB) buffer prior to analysis and detected by laser-induced native fluorescence using a pulsed Nd:YAG laser. During the concentration and separation, PEO solution entered the capillary by electroosmotic flow. When proteins dissolved in high salts (phosphate-buffered saline) were separated using 0.6% PEO solution prepared in 200 mM TB buffer, pH 9.0, the limits of detection (LODs) at signal-to noise ratios=3 for carbonic anhydrase (CA) and alpha-lactalbumin (alpha-lac) were on the levels of sub microM and microM, respectively. The LOD values compared to those obtained in 38 mM TB buffer were relatively high, which is likely due to salt quenching, Joule heating and poor stacking. To improve sensitivity for analysis of proteins in high-conductivity media, two on-line concentration approaches without desalting were developed. When using a capillary filled with 1.5 M TB buffer, pH 10.0, and PEO solution prepared in 800 mM TB buffer, pH 9.0, the LOD values for CA and alpha-lac were 13.8 nM and 126.0 nM, respectively, which were about 4.7 and 11.2-fold sensitivity enhancements compared to those obtained by a conventional hydrodynamic injection (30 cm height for 10 s), respectively. The sensitivity was further improved by injecting a short plug of low pH buffer after protein injection using a capillary filled with 1.5 M TB buffer, pH 10.0, and PEO solution prepared in 400 mM TB buffer, pH 9.0. A linear relationship between the peak height and the injection volume up to 0.81 microl was obtained and the LOD values for CA and alpha-lac were down to 4.7 and 37.8 nM.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Capillary Electrophoresis: Instrumentation
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...

