Administration of 100% oxygen in diving accidents--an evaluation of four emergency oxygen devices
U Hoffmann1, M Smerecnik, C M Muth
1Department of Physiology, German Sport University, Cologne. HOFFMANN@HRZ.DSHS-KOELN.DE
Abstract:
As the use of oxygen enhances the resorption of gas bubbles in decompression illness, it is recommended and generally accepted that the inspired oxygen concentration in emergency treatment of diving accidents has to be as close to 100% as possible. Therefore, several emergency oxygen devices are offered to the diving community but only with little data in literature on the efficacy of these devices. We tested four emergency oxygen devices with respect to efficacy of oxygen supply and breathing comfort at rest. Nine blinded volunteers had to breathe from the four systems with face mask and mouthpiece as well. Gases were measured with mass spectrometry during a 3 min interval from a capillary port close to the subject. The results showed that none of the systems was able to deliver 100% oxygen all the time, but in three systems inspiratory oxygen values were achieved, although in one system the nitrogen wash-out was slowed due to air contamination during inspiration. The fourth tested system frequently supplied the subjects simply with air while breathing at rest. We conclude from our study that it is difficult to achieve oxygen levels close to 100% in practice. Even in a perfectly working system, the interface between device and subject is a source of entrained air, especially when oxygen breathing has to be performed over a longer period of time. In addition, two of four systems had conceptional problems to supply the subjects with pure O2 during inspiration. None of the tested systems was perfectly designed to serve in such emergencies.
Related Concept Videos
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management