Early high-frequency oscillatory ventilation versus synchronized intermittent mandatory ventilation in very low birth
D J Durand1, J M Asselin, M L Hudak
1Division of Neonatology, Children's Hospital Oakland, Oakland, CA 94609, USA.
Objective:
To evaluate the feasibility of conducting a prospective, randomized trial comparing early high-frequency oscillatory ventilation (HFOV) to synchronized intermittent mandatory ventilation (SIMV) in very low birth weight (VLBW) premature infants. This pilot study evaluated two ventilator management protocols to determine how well they could be implemented in a multicenter clinical trial. Although this pilot study was not powered to detect differences in outcome, we also collected outcome data.
Design:
Prospective, multicenter, randomized pilot study.
Setting:
Seven tertiary-level intensive care nurseries with previous experience with both HFOV and flow-triggered SIMV.
Patients:
Fifty infants weighing 501 to 1200 g, less than 4 hours of age, who had received one dose of surfactant and required ventilation with mean airway pressure > or =6 cm H2O and F(I)O2 > or =0.25, and had an anticipated duration of ventilation greater than 24 hours.
Interventions:
Patients were stratified by birth weight and prenatal steroid status, then randomized to either HFOV or SIMV with tidal volume monitoring. Ventilator management for patients in both study arms was strictly governed by protocols that included optimizing lung inflation and blood gases, weaning strategies, and extubation criteria.
Measurements:
Data were collected using the tools planned for the larger collaborative study. Protocol compliance was closely monitored, with successive changes in the protocol made as necessary to improve clarity and increase compliance. The incidence of major neonatal adverse outcomes was recorded.
Main Results:
Data are presented for 24 HFOV and 24 SIMV infants (two infants, twins, were withdrawn from the study at parent's request). Nineteen of the 24 HFOV infants and 20 of the 24 SIMV infants survived to 36 weeks corrected age. Age at final extubation for survivors was 16+/-16 (mean+/-SD) days for HFOV infants and 24+/-24 days for SIMV infants. At 36 weeks corrected age, 14 of the 19 HFOV survivors were extubated and in room air, whereas 5 required supplemental oxygen. In comparison, 6 of the 20 SIMV survivors were extubated and in room air, whereas 14 required supplemental oxygen. Grade III/IV IVH and/or periventricular leukomalacia occurred in 2 HFOV and 2 SIMV patients. Overall compliance with the ventilator protocols was 82% for the SIMV protocol, and 88% for the HFOV protocol.
Conclusions:
The preliminary outcome data supports conducting the large randomized trial, which began in July of 1998. The protocols for the ventilator management of VLBW infants, both with HFOV and with SIMV were easily implemented and consistently followed, and are presented here.
More Related Videos
07:15Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes