Related Experiment Video
Updated: Oct 4, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
The use of a pressure manometer enhances student physiotherapists' performance during manual hyperinflation
1School of Physiotherapy, The University of Sydney, Lidcombe, NSW, 1825, Australia.
Abstract:
The purpose of this study was to determine the effect of using a pressure manometer on the delivery of target airway pressures during manual hyperinflation by student physiotherapists in the laboratory and clinical environments. Manual hyperinflations were delivered under control and feedback conditions where the feedback condition involved manual hyperinflation with a pressure manometer. Compared with control conditions, the availability of a manometer significantly decreased the mean absolute error (9.5 +/- 0.9 cm H2O to 1.4 +/- 0.2 cm H2O) and mean variable error (2.2 +/- 0.3 cm H2O to 1.3 +/- 0.1cm H2O) of peak airway pressures during manual hyperinflation. In addition, the availability of a manometer negated the influence of environment on accuracy. Therefore, the availability of a pressure manometer provided an effective clinical tool that was easily used to provide feedback regarding the peak airway pressures delivered during manual hyperinflation.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
