Kinetic studies on the mechanism of atomization in electrothermal atomic absorption spectrometry with and without
1Research Center for Analytical Sciences, College of Chemistry, Nankai University, Tianjin, China. xpyan@nankai.edu.cn
Abstract:
Over the past decade a few methods for determining kinetic data for atom formation from the absorption signal in electrothermal atomic absorption spectrometry (ETAAS) have been developed in the author's laboratory. These approaches include improvement to the Smets method, and development of new methods for simultaneous determination of kinetic order and activation energy for atom formation at increasing or constant temperatures. The steady-state approximation and first-order kinetic assumption for atom formation have been avoided during their derivation. One of the most distinct features of these new methods is their suitability for quantitative determination of the kinetic order for atom formation from absorption signals under normal analytical conditions, even for atomization processes with fractional reaction orders and/or with multiple mechanisms. The application of the developed methods to the study of the mechanism of atomization in the graphite-furnace atomizer, with and without chemical modifiers, is reviewed with emphasis on research work in the authors' laboratory.
More Related Videos
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
07:24Combustion Chemistry of Fuels: Quantitative Speciation Data Obtained from an Atmospheric High-temperature Flow Reactor with Coupled Molecular-beam Mass Spectrometer
Published on: February 19, 2018
Related Concept Videos
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Instrumentation
Atomic Emission Spectroscopy: Interference