A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Enhanced detection criteria in implantable cardioverter defibrillators: sensitivity and specificity of the stability
K Kettering1, V Dörnberger, R Lang
1Dept. of Cardiology, University of Tübingen, Otfried-Müller-Strasse 10, 72076 Tübingen, Germany. Klaus.Kettering@t-online.de
Abstract:
The lack of specificity in the detection of ventricular tachyarrhythmias remains a major clinical problem in the therapy with ICDs. The stability criterion has been shown to be useful in discriminating ventricular tachyarrhythmias characterized by a small variation in cycle lengths from AF with rapid ventricular response presenting a higher degree of variability of RR intervals. But RR variability decreases with increasing heart rate during AF. Therefore, the aim of the study was to determine if the sensitivity and specificity of the STABILITY algorithm for spontaneous tachyarrhythmias is related to ventricular rate. Forty-two patients who had received an ICD (CPI Ventak Mini I, II, III or Ventak AV) were enrolled in the study. Two hundred ninety-eight episodes of AF with rapid ventricular response and 817 episodes of ventricular tachyarrhythmias were analyzed. Sensitivity and specificity in the detection of ventricular tachyarrhythmias were calculated at different heart rates. When a stability value of 30 ms was programmed the result was a sensitivity of 82.7% and a specificity of 91.4% in the detection of slow ventricular tachyarrhythmias (heart rate < 150 beats/min). When faster ventricular tachyarrhythmias with rates between 150 and 169 beats/min (170-189 beats/min) were analyzed, a stability value of 30 ms provided a sensitivity of 94.5% (94.7%) and a specificity of 76.5% (54.0%). For arrhythmia episodes > or = 190 beats/min, the same stability value resulted in a sensitivity of 78.2% and a specificity of 41.0%. Even when other stability values were taken into consideration, no acceptable sensitivity/specificity values could be obtained in this subgroup. RR variability decreases with increasing heart rate during AF while RR variability remains almost constant at different cycle lengths during ventricular tachyarrhythmias. Thus, acceptable performance of the STABILITY algorithm appears to be limited to ventricular rate zones < 170 beats/min.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Dysrhythmias V: Evaluating Dysrhythmias
Heart Failure IV: Classification and Diagnostic Evaluation