Related Experiment Video
Updated: Oct 4, 2026

Imaging Features of Systemic Sclerosis-Associated Interstitial Lung Disease
Published on: June 16, 2020
[An assessment of low-dose high resolution CT in the detection of benign asbestos-related pleural abnormalities]
1Service de Radiologie et Imagerie Médicale, Hôpital Gabriel Montpied, Centre Hospitalier Universitaire, BP 69, 63003 Clermont-Ferrand Cedex 1, France.
Purpose:
To assess the reliability of low-dose high-resolution computed tomography (HRCT) in the detection of benign asbestos-related pleural abnormalities.
Methods:
Fourty-one patients exposed to asbestos were imaged on two occasions; the first time with conventional HRCT parameters: 140kVp, 220mAs; the second time with low-dose HRCT parameters: 120kVp, 60mAs.
Results:
The qualitative assessment dit not show any difference in the visibility of benign pleural abnormalities from one technique to the other in 98% cases.
Conclusion:
The detection of pleural plaques and thickening did not vary with the two scanning protocols and, when compared with conventional HRCT, low-dose HRCT allows reduced radiation exposure by at least 76.5%, with an absorbed dose close to that delivered when using conventional chest radiography. Nevertheless, low-dose HRCT is a complementary study to helical acquisitions.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Pleural Disorders: Types and Brief Description
Radiological Investigation I: X-ray and CT