An evaluation of occlusal contact marking indicators. A descriptive quantitative method.
1Tufts University School of Dental Medicine, Boston, Mass., USA. pmillstein@aol.com
Journal of the American Dental Association (1939)
|October 23, 2001
Summary
Occlusal contact indicators used in dentistry vary significantly in accuracy and repeatability. Material, thickness, and color affect markings, necessitating further research for a reliable occlusal marking standard.
Area of Science:
- Dental materials science
- Biomechanical analysis of occlusion
Background:
- Accurate recording of occlusal contacts is crucial in dentistry.
- Current occlusal contact marking indicators lack consistent accuracy and reproducibility.
Purpose of the Study:
- To evaluate the accuracy and reproducibility of various occlusal contact marking indicators.
- To identify factors influencing the performance of these indicators.
Main Methods:
- Ten different occlusal indicators (paper, film, silk) were tested.
- Contact areas were measured on articulator-mounted casts using advanced imaging analysis.
- Factors like indicator material, thickness, and color were analyzed for their impact on markings.
Main Results:
- Significant variations in marking surface areas were observed both between and within indicator groups.
- Indicator thickness, color, and material composition demonstrably affected marking size.
- Repeatability of markings was inconsistent across different indicators.
Conclusions:
- Existing occlusal contact indicators exhibit variability, potentially leading to misleading interpretations of occlusal disharmony.
- Development of a standardized, accurate occlusal marking indicator is essential.