Electrochemiluminescence Assays for Human Islet Autoantibodies
Published on: March 23, 2018
Homogeneous preparation of fluorescent-derivatized insulin and its application to competitive chromatographic
H J Liu1, R E Strong, I S Krull
1Department of Chemistry, Northeastern University, 102 Hurtig Building, 360 Huntington Avenue, Boston, Massachusetts 02115, USA.
A homogeneously labeled insulin sample was prepared using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) as the fluorescent-labeling reagent, and this was successfully applied to a chromatographic immunoassay. This labeled insulin was prepared by tagging all the three amino groups with AQC. Both CE and chromatographic immunoassay experiments indicated that the prepared insulin still kept its immunoaffinity to its antibody. It was observed that appropriate concentrations of acetonitrile (ACN) were efficient in lowering the quenching of the fluorescent signal of tagged insulin, in keeping the dilute, tagged insulin in solution, and in improving its peak shape during a chromatographic immunoassay. The tagged insulin was found to be 20-400 times more sensitive than native insulin detected under ultraviolet detection conditions. A competitive chromatographic immunoassay system was set up and calibrated. The system was used for analyses of an insulin-spiked urine sample, with a 96% recovery obtained.
A homogeneously labeled insulin sample was prepared using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) as the fluorescent-labeling reagent, and this was successfully applied to a chromatographic immunoassay. This labeled insulin was prepared by tagging all the three amino groups with AQC. Both CE and chromatographic immunoassay experiments indicated that the prepared insulin still kept its immunoaffinity to its antibody. It was observed that appropriate concentrations of acetonitrile (ACN) were efficient in lowering the quenching of the fluorescent signal of tagged insulin, in keeping the dilute, tagged insulin in solution, and in improving its peak shape during a chromatographic immunoassay. The tagged insulin was found to be 20-400 times more sensitive than native insulin detected under ultraviolet detection conditions. A competitive chromatographic immunoassay system was set up and calibrated. The system was used for analyses of an insulin-spiked urine sample, with a 96% recovery obtained.
More Related Videos
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Immunofluorescence Microscopy
The...