Related Experiment Video
Updated: Aug 2, 2026

Waste Water Derived Electroactive Microbial Biofilms: Growth, Maintenance, and Basic Characterization
Published on: December 29, 2013
Microbial corrosion monitoring by an amperometric microbial biosensor developed using whole cell of Pseudomonas sp
1Department of Chemical Engineering and Technology, Centre of Advanced Study, Banaras Hindu University, Varanasi 221005, India. dubey_rsagar@rediffmail.con
Abstract:
A microbial biosensor was developed for monitoring microbiologically influenced corrosion (MIC) of metallic materials in industrial systems. The Pseudomonas sp. isolated from corroded metal surface was immobilized on acetylcellulose membrane and its respiratory activity was estimated by measuring oxygen consumption. The microbial biosensor was used for the measurement of sulfuric acid in a batch culture medium contaminated by microorganisms. A linear relationship between the microbial sensor response and the concentration of sulfuric acid was observed. The response time of biosensor was 5 min and was dependent on the immobilized cell loading of Pseudomonas sp., pH, temperature and corrosive environments. The microbial biosensor response was stable, reproducible and specific for sensing of sulfur oxidizing bacterial activity.