Related Experiment Video
Updated: Jul 28, 2026

13:13
Biochemical Measurement of Neonatal Hypoxia
Published on: August 24, 2011
Problems in the measurement of Lp(a) (millimoles per liter versus milligrams percent)
Journal of the American College of Cardiology
|November 3, 2001
Abstract
No abstract available in PubMed .
Related Concept Videos
Expressing Solution Concentration
A solute is a component of a solution that is typically present at a much lower concentration than the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
Difference from Background: Limit of Detection
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
The LOD indicates the presence or absence...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Drug Concentrations: Measurements
Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma —...
Plasma —...
Microbial Growth Measurement: Direct Methods
Direct methods for measuring microbial populations in a culture are essential tools in microbiology, providing quantitative data for various applications. Among these, microscopic counts, plate counts, and serial dilution are widely used techniques, each with unique principles and applications.Microscopic CountsMicroscopic counting involves the use of a Petroff-Hausser chamber, a specialized microscope slide with a grid and defined depth. By observing a liquid culture under a microscope,...
Applications of Logarithms
Logarithmic functions are powerful tools for simplifying the mathematical representation of phenomena involving exponential changes. Their ability to convert multiplicative relationships into additive ones is especially valuable in various scientific and engineering contexts. One notable application of logarithms is measuring sound intensity, specifically through the decibel (dB) scale used in acoustics.Sound intensity levels vary over an extensive range, from the faintest audible whisper to...

