Related Experiment Video
Updated: Oct 3, 2026

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Assessment of left atrial appendage filling pattern by using intravenous administration of microbubbles: comparison
1Cardiology Division, Yonsei Cardiovascular Center, Yonsei University College of Medicine, Seoul, South Korea.
Abstract:
Mitral stenosis (MS) and mitral regurgitation (MR) are the most frequent conditions that cause a dilation and dysfunction of the left atrial appendage (LAA). Despite similarly dilated LAA in patients with MS and MR, the incidence of LAA thrombi and the risk of thromboembolism is different between these patients. The purpose of this study was to characterize the filling pattern of LAA by using intravenous administration of perfluorocarbon-exposed dextrose albumin (PESDA) during transesophageal echocardiographic examination in patients with MS and MR. Twenty-four patients with moderate to severe MS, 12 patients with severe MR, and a control group including 30 patients with conditions other than mitral valve disease underwent transesophageal echocardiographic examination with an intravenous bolus injection of PESDA. LAA emptying and filling velocities and maximal and minimal areas of LAA and LAA ejection fraction were measured. Digital gray-scale intensity (GSI) of the left atrial (LA) and LAA cavity after PESDA injection was measured by off-line analysis. Compared with control patients, patients with MS or MR had larger maximal and minimal areas of LAA and reduced LAA ejection fraction. LAA peak emptying flow velocity was significantly lower in patients with MS compared with those of MR or control patients. LAA peak filling velocity was significantly lower in patients with MS compared with that of control patients. However, there was no significant difference of LAA peak filling velocity between the patients with MS and MR. There was no significant difference of GSI ratio of LAA and LA between patients with MR and control patients; however, GSI ratio of LAA and LA was significantly lower in patients with MS compared with that of MR. The incidence of LAA spontaneous echo contrast and LAA thrombi in patients with MS was significantly higher than that of the patients with MR and control subjects (P <.005). Despite similarly dilated LAA area and depressed contractile function of LAA in patients with MS and MR compared with control patients, profoundly impaired LAA filling with resultant flow stasis was demonstrated by contrast echocardiography in patients with MS. These findings may explain the higher incidence of LAA spontaneous echo contrast and thrombus in patients with MS.
More Related Videos
08:17Murine Echocardiography of Left Atrium, Aorta, and Pulmonary Artery
Published on: February 20, 2017
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Regurgitation I: Introduction
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis I: Introduction