Dose homogeneity as a function of source activity in optimized I-125 prostate implant treatment plans
1Department of Medical Physics, University of Wisconsin, Madison, WI, USA. wdsouza@mdanderson.org
Purpose:
In conventional treatment planning for permanent I-125 prostate implants, it has been suggested that lower seed activities result in more homogeneous dose distributions and also less overdose of the critical structures. We sought to determine if this hypothesis holds by analyzing treatment plans constructed using an automated optimized approach.
Methods And Materials:
We studied treatment plans for 10 patients using mixed-integer programming and the branch-and-bound method. Two mixed-integer models (that yielded somewhat different treatment plans) were developed: a "basic" model and a "dose homogeneity" model. For each resulting treatment plan, we examined dose homogeneity (by evaluating the dose non-uniformity ratio [DNR] and the full-width half-maximum [FWHM] of the differential dose-volume histogram [DVH]) as a function of three different source activities (0.35 mCi, 0.44 mCi, and 0.66 mCi). In addition, target coverage and critical structure dose distributions were evaluated. Plans using multiple source activities were also evaluated for resulting dose inhomogeneities.
Results:
The homogeneity model results in a more homogeneous dose distribution than the basic model. DNR is lowered by an average of 42% (standard deviation [SD] = 19%), 39% (SD = 21%), and 33% (SD = 21%) for the 0.35 mCi, 0.44 mCi, and 0.66 mCi seeds, respectively, when the homogeneity model is employed over the basic model. Corresponding average decreases in the FWHM of the DVH for 0.35 mCi, 0.44 mCi, and 0.66 mCi, respectively, are 29 Gy (SD = 28 Gy), 24 Gy (SD = 22 Gy), and 27 Gy (SD = 13 Gy). Seeds of 0.35 mCi and 0.44 mCi result in the lowest DNR and narrower FWHM of the DVH relative to 0.66 mCi seeds. In general, the 0.44 mCi seeds produce greater target coverage and require fewer seeds and needles than the 0.35 mCi seeds. Although 0.66 mCi seeds result in the greatest target coverage, they yield highest critical structure doses. They also yield solutions requiring the least number of seeds and needles. However, the dose distributions from 0.66 mCi seeds are highly inhomogeneous. Multiple source activities in the same treatment plan produce dose distributions that are comparable in homogeneity to 0.44 mCi seed implants.
Conclusions:
Even when an optimization model that seeks to minimize dose inhomogeneity is employed, all factors involved in seed implants make 0.44 mCi the best activity choice in comparison with 0.35 mCi and 0.66 mCi.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Dosage Regimen: Individualization