Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

A forward model-based validation of cardiovascular system identification.

R Mukkamala1, R J Cohen

  • 1Harvard-Massachusetts Institute of Technology Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, 02139, USA. rmukkama@mit.edu

American Journal of Physiology. Heart and Circulatory Physiology
|November 16, 2001
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Cardiac output is not a significant source of low frequency mean arterial pressure variability.

Physiological measurement·2013
Same author

Continuous and minimally invasive cardiac output monitoring by long time interval analysis of a radial arterial pressure waveform: assessment using a large, public intensive care unit patient database.

British journal of anaesthesia·2012
Same author

Monitoring non-invasive cardiac output and stroke volume during experimental human hypovolaemia and resuscitation.

British journal of anaesthesia·2010
Same author

Plasma concentration of Propionibacterium acnes antibodies and prostate cancer risk: results from an Australian population-based case-control study.

British journal of cancer·2010
Same author

Prostate biopsy in Western Australia 1998-2004.

Prostate cancer and prostatic diseases·2010
Same author

Esophageal motion during radiotherapy: quantification and margin implications.

Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus·2010

This study validates a cardiovascular system identification method for analyzing beat-to-beat variability. The method accurately characterizes autonomic and mechanical mechanisms, proving robust and sensitive for experimental data analysis.

Area of Science:

  • Physiology
  • Biomedical Engineering
  • Systems Biology

Background:

  • Beat-to-beat variability in cardiovascular signals (heart rate, blood pressure, lung volume) reflects autonomic and mechanical control.
  • Accurate characterization of these physiological mechanisms is crucial for understanding cardiovascular dynamics.
  • Previous development of a cardiovascular system identification method for analyzing these fluctuations.

Purpose of the Study:

  • To theoretically evaluate a previously developed cardiovascular system identification method.
  • To assess the method's ability to dynamically characterize autonomic and mechanical coupling mechanisms.
  • To confirm the method's robustness and sensitivity using a computational model.

Main Methods:

  • Development of a computational cardiovascular system model for generating realistic beat-to-beat variability (forward modeling).
Keywords:
NASA Discipline CardiopulmonaryNon-NASA Center

Related Experiment Videos

  • Application of the cardiovascular system identification method (inverse modeling) to simulated data.
  • Comparison of estimated dynamics from the method against known dynamics of the forward model.
  • Main Results:

    • The identification method accurately estimated the cardiovascular system's dynamics.
    • The method's performance remained robust despite uncertainties in the forward model.
    • The method demonstrated sensitivity in detecting subtle alterations in autonomic function parameters.

    Conclusions:

    • The theoretical evaluation provides strong confidence in the cardiovascular system identification method.
    • The method is reliable for analyzing beat-to-beat variability in experimental cardiovascular data.
    • This validation supports the use of the method for characterizing autonomic and mechanical regulatory mechanisms.