Related Experiment Video
Updated: Jul 27, 2026

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Flowmetric comparison of respiratory inductance plethysmography and pneumotachography in horses
A Hoffman1, H Kuehn, K Riedelberger
1Department of Clinical Sciences, Tufts University School of Veterinary Medicine, North Grafton, MA 01536, USA. andrew.hoffman@tufts.edu
Abstract:
Respiratory inductance plethysmographic (RIP) and pneumotachographic (Pn) flows were compared dynamically in horses with bronchoconstriction. On a breath-by-breath basis, RIP was normalized to inspiratory volume from Pn, and peak [peak of subtracted final exhalation waveform (SFE(max))] and selected area [integral of subtracted final waveform during first 25% of exhaled volume (SFE(int))] differences between RIP and Pn flows during early expiration were measured in three settings: 1) healthy horses (n = 8) undergoing histamine bronchoprovocation; 2) horses with naturally occurring lower airway obstruction (AO) (n = 7); and 3) healthy horses (n = 6) given lobeline. HCl to induce hyperpnea. In setting 1, histamine challenge induced a dose-dependent increase in SFE(max) and SFE(int) differences. A test index of airway reactivity (interpolated histamine dose that increased SFE(max) by 35%) closely correlated (r(s) = 0.93, P = 0.001) with a conventional index (histamine dose that induced a 35% decrease in dynamic compliance). In setting 2, in horses with AO, SFE(max) and SFE(int) were markedly elevated, and their absolute values correlated significantly (P < 0.005) with pulmonary resistance and the maximum change in transpulmonary pressure. The effects of bronchodilator treatment on the SFE(max) and SFE(int) were also highly significant (P < 0.0001). In setting 3, hyperpnea, but not tachypnea, caused significant (P < 0.01) increases in SFE(max) but not in SFE(int). In conclusion, dynamic comparisons between RIP and Pn provide a defensible method for quantifying AO during tidal breathing, without the need for invasive instrumentation.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: