Related Experiment Videos
Development of a hybrid finite element model for individual simulation of intertrochanteric osteotomies
J Schmitt1, J Meiforth, M Lengsfeld
1Department of Orthopaedic Surgery, Philipps-University of Marburg, Baldingerstrasse, D-35033 Marburg/Lahn, Germany. schmitt2@mailer.uni-marburg.de
Abstract:
Intertrochanteric osteotomies of the proximal femur are used to improve the anatomy and function of the hip joint in a number of orthopaedic diseases. To investigate the geometrical and biomechanical aspects of pre-operative planning we created a set of programs to automatically perform a simulation of intertrochanteric osteotomies on a three-dimensional finite element model of the human proximal femur based on computed tomography (CT) data and using uniform brick-shaped elements. To eliminate artefacts resulting from the rough surface of the brick elements, the femoral head was represented by a tetrahedron-based head that included a cartilage layer and a subchondral cortical zone. Applicability of the procedure was tested by performing a parametric study using a model created from CT scans taken in vivo, by applying individually calculated force conditions for the one-leg stance situation. We found a large influence of osteotomy angle on the observed stress in the femoral head cartilage, especially in a situation with insufficient containment of the femoral head. The model presented here is a biomechanical tool to simulate intertrochanteric osteotomies patient-specifically for a better understanding of the effects of such operations in the individual case. The open design of the described programs allows future interfacing with surgical navigation and robot systems.