Use of a Low-flow Digital Anesthesia System for Mice and Rats
Published on: September 7, 2016
Model-based automatic feedback control versus human control of end-tidal isoflurane concentration using low-flow
T J Sieber1, C W Frei, M Derighetti
1Department of Anaesthesiology, Research Section, University of Berne, Inselspital, Switzerland.
Abstract:
We studied the clinical use of an automatic feedback control system to adjust the end-tidal anaesthetic concentration with a low-flow method. The end-tidal controller uses two input signals (the end-tidal and inspiratory concentrations) to control the isoflurane concentration in the fresh gas flow, using a model-based algorithm. We studied 22 ASA I-III patients during elective surgery lasting more than 2 h. The anaesthetist was asked to make four step changes of the target end-tidal concentration (+0.3, +0.6, -0.3, -0.6 vol%), either manually (Group A) or by setting the target value for the feedback controller (Group B), and then the control was changed and the step changes were repeated, in a crossover design. Eighty step changes with each control method were compared in terms of response time, maximal overshoot and stability. The automatic control system was more accurate and stable than the human controller for step increases and step decreases, with less overshoot/undershoot and greater stability [e.g. maximal overshoot 14.7 (SD 3.7)% and 18 (8.1)% respectively for +0.6 vol% step changes, and 19.8 (3.7)% and 30.7 (13.2)% respectively for +0.3 vol% step changes]. However, the automatic control system showed a faster response time than the manual method only with large increasing steps (e.g. 149 (32) s and 205 (57) s respectively for +0.6 vol% step changes) and was not different from manual control for decreasing steps. Automatic control of the end-tidal isoflurane concentration can be better than human control in a clinical setting, and this task could be done automatically.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...