Determination of iodide in urine by ion-pair chromatography with electrochemical detection
1Ernst Moritz Arndt University Greifswald, Institute of Hygiene and Environmental Medicine, Greifswald, Germany. below@mail.uni-griefswald.de
A variety of parameters affecting the determination of iodide in biological materials by ion-pair chromatography and electrochemical detection were examined in detail. It became apparent that the pH value, the ion-pair concentration, the proportion of organic solvent and of organic bases as a component of the buffer solution, as well as the salt concentration in the eluent system could effectively influence the retention characteristics of iodide in the chromatographic system, resulting in the separation of potential interfering substances. The presence of other anions in the sample matrix has to be taken into consideration, particularly thiocyanate because of its long retention time. Investigations of the electrochemical detection mechanism revealed that the reaction hitherto assumed to be responsible for detector signal generation (formation of AgI) is incorrect. In addition, a much more sensitive detection of iodide than that cited in the literature to date is possible if the detector potential is optimally selected and any anticipated interfering substances are removed by chromatography. Use of a gold electrode rather than a silver electrode also considerably enhances the reliability of the procedure.
A variety of parameters affecting the determination of iodide in biological materials by ion-pair chromatography and electrochemical detection were examined in detail. It became apparent that the pH value, the ion-pair concentration, the proportion of organic solvent and of organic bases as a component of the buffer solution, as well as the salt concentration in the eluent system could effectively influence the retention characteristics of iodide in the chromatographic system, resulting in the separation of potential interfering substances. The presence of other anions in the sample matrix has to be taken into consideration, particularly thiocyanate because of its long retention time. Investigations of the electrochemical detection mechanism revealed that the reaction hitherto assumed to be responsible for detector signal generation (formation of AgI) is incorrect. In addition, a much more sensitive detection of iodide than that cited in the literature to date is possible if the detector potential is optimally selected and any anticipated interfering substances are removed by chromatography. Use of a gold electrode rather than a silver electrode also considerably enhances the reliability of the procedure.
More Related Videos
09:54Chemoselective Preparation of 1-Iodoalkynes, 1,2-Diiodoalkenes, and 1,1,2-Triiodoalkenes Based on the Oxidative Iodination of Terminal Alkynes
Published on: September 12, 2018
07:28An Efficient Method for Selective Desalination of Radioactive Iodine Anions by Using Gold Nanoparticles-Embedded Membrane Filter
Published on: July 13, 2018
Related Concept Videos
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Redox Titration: Iodimetry and Iodometry
Precipitation Titration Curve: Analysis
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Indirect and Alkalimetric Titration
Ion-Exchange Chromatography