Related Experiment Video
Updated: Aug 14, 2026

A Step Beyond BRET: Fluorescence by Unbound Excitation from Luminescence (FUEL)
Published on: May 23, 2014
Chemiluminescence flow sensor for folic acid with immobilized reagents
1Department of Chemistry, Northwest University, Xian, People's Republic of China. songzhenghua@hotmail.com
Abstract:
A novel chemiluminescence (CL) sensor for folic acid combined flow-injection (FI) technology was presented in this paper. The analytical reagents involved in the CL reaction, including luminol and hexacyanoferrate(III), were both immobilized on an anion-exchange column in FI system. The CL signal produced by the reaction between luminol and hexacyanoferrate(III), which were eluted from the column through sodium phosphate injection, was decreased in the presence of folic acid. The CL emission was correlated with the folic acid concentration in the range from 0.01 to 15 microg ml(-1), and the detection limit was 3.5 ng ml(-1) folic acid (3sigma). At a flow rate of 2.0 ml min(-1), including sampling and washing, could be performed in 2 min with a relative standard deviation of < 2.5%. The flow sensor could be reused more than 300 times and has been applied to the analysis of folic acid in pharmaceutical preparations. and the recovery was from 97.4% to 100.4%.

