Certification of the chlorine content of the isotopic reference materials IRMM-641 and IRMM-642

M Ostermann1, M Berglund, P D Taylor

  • 1Institute for Reference Materials and Measurements, European Commission-Joint Research Center, Geel, Belgium.

Related Concept Videos

Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Mass Spectrometry: Alkyl Halide Fragmentation01:22

Mass Spectrometry: Alkyl Halide Fragmentation

Chlorine isotopes exist as 35Cl and 37Cl in a 3:1 ratio, while bromine isotopes exist as 79Br and 81Br in a 1:1 ratio. The mass spectrum of alkyl halides typically produces two distinct molecular ion peaks, the molecular ion peak, [M], and the molecular ion plus two, [M + 2] peak. The relative heights of these two peaks are proportional to the isotopic abundance ratios of the halide. For example, 2‐chloropropane and 1‐bromopropane display two peaks with relative peak heights in a 3:1 and 1:1...
Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
Redox Titration: Iodimetry and Iodometry01:23

Redox Titration: Iodimetry and Iodometry

Iodometry and iodimetry are analytical methods used to determine the concentration of oxidizing or reducing agents using iodine. In iodometric titrations, the oxidizing analyte solution is usually acidified and treated with an excess of iodide ions, which generates an equivalent amount of iodine in equilibrium with triiodide. The released iodine is subsequently titrated directly against a standardized reducing agent. As the dilute iodine color becomes pale yellow, a few drops of freshly...
EDTA: Indirect and Alkalimetric Titration01:23

EDTA: Indirect and Alkalimetric Titration

Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...