Assessment of cardiac viability by thallium 201 redistribution and dobutamine echocardiography
Related Experiment Video
Updated: Oct 3, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
José Luis Zamorano1, Juan Delgado, Carlos Almería
1Hospital Clínico San Carlos and the Hospital 12 de Octubre de Madrid, Madrid, Spain. jlzamorano@jet.es
Insights
Dobutamine echocardiography and thallium 201 have different detection thresholds for myocardial viability. These differences in minimum viable myocyte mass explain the conflicting results observed between these two diagnostic tests.
Area of Science:
- Cardiology
- Medical Imaging
- Pathology
Background:
- Dobutamine echocardiography and thallium 201 are used to assess myocardial viability.
- These techniques often produce conflicting results, hindering accurate diagnosis.
Purpose of the Study:
- To determine the minimum mass of viable myocardium detectable by each test.
- To compare the agreement between dobutamine echocardiography and thallium 201 in detecting myocardial viability.
Main Methods:
- 10 patients undergoing cardiac transplantation had dobutamine echocardiography and thallium 201 performed.
- 15 myocardial segments per patient were analyzed post-transplantation for viable myocyte percentage.
- Viable tissue percentage was compared with test results (viable/non-viable).
Main Results:
- Thallium 201 identified more segments as viable (78%) than dobutamine echocardiography (60%).
- The minimum viable tissue percentage detected was 43% for thallium 201 and 49% for echocardiography.
- Echocardiography showed higher accuracy (LR+ 5.5, LR- 7.7) at 31% necrotic tissue compared to thallium 201 (LR+ 2.2, LR- 3.6) at 40% necrotic tissue.
Conclusions:
- Discrepancies between dobutamine echocardiography and thallium 201 stem from differing minimum viable myocyte mass requirements.
- Understanding these differences is crucial for interpreting myocardial viability assessments.
Objective:
Dobutamine echocardiography and thalium 201 are useful in the assessment of myocardial viability, but both techniques frequently yield conflicting results. The objective of this study was to determine the minimum mass of viable myocardium that each test could detect and compare the agreement of dobutamine echocardiography and thallium 201 to detect viability.
Methods:
Dobutamine echocardiography and thallium 201 were performed in 10 patients scheduled for cardiac transplantation. In each patient, 15 segments were studied. After transplantation these segments were analyzed by the pathologist measuring by a computer system the total area of each segment, the necrotic + fatty mass, and area (%) of viable myocytes per segment. The percentage of viable tissue was estimated ([Total mass - (Necrotic + Fatty tissue)]/Total mass x 100) on each segment, which was compared with the result (viable or not viable) obtained by echocardiography or thallium 201.
Results:
Dobutamine echocardiography defined 90 segments (60%) as viable versus 117 (78%) in thallium (kappa 0.49, 95% CI 0.36-0.63). The minimum percent of viable tissue per segment defined as viable by thallium was 43% versus 49% by echocardiography. With use of thallium, the highest accuracy of the test to detect viability was when the percent of necrotic tissue of the segment analyzed was 40% (positive and negative likelihood ratio 2.2 and 3.6, respectively). By use of echocardiography, the highest accuracy of the test was observed when the percent of necrotic tissue of the segment analyzed was 31% (positive and negative likelihood ratio 5.5 and 7.7, respectively).
Conclusion:
The discrepant results of dobutamine echocardiography and thallium 201 are due to differences in the minimum mass of live myocytes required by each technique to detect viability.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System V: CT