Related Experiment Video
Updated: Jul 26, 2026

Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Identification of pharmaceutical glasses by laser ablation ICP-MS
T Schmidt1, J P Surmann, H Stephanowitz
1Institute of Pharmacy, Humboldt University, Berlin, Germany.
Abstract:
The chemical composition of pharmaceutical glasses (ampoules, infusion bottles, plunger) has been determined by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). A Nd:YAG laser with 10 Hz repetition rate in the Q-switch mode at its fundamental wavelength (1064 nm) was used to identify common types of pharmaceutical glasses. The following isotopes were used for measurements: 7Li, 11B, 23Na, 24Mg, 27Al, 28Si, 29Si, 30Si, 39K, 42Ca, 47Ti, 57Fe, 90Zr, 121Sb, 137Ba. Each analysis included the measurement of 12 craters. Relative standard deviations between 1.8% and 8.0% of the quantitative results were obtained. 29Si was used as internal standard. Standard reference materials (soda-lime-, lead- and borosilicate glasses) were used for external calibration of laser sampling. Linear calibration functions for each isotope were found. All samples and standard materials were digested in a two-step-procedure by nitric/fluoric acid, then measured and externally calibrated by ICP-MS with multi-elemental standard solutions using 45Sc as internal standard. Digestion and laser ablation results agree within 8% (confidential interval 95%) with the certified values. Intensity ratios of most isotopes also agree sufficiently with the corresponding theoretical values (+/- 18%). The developed method allows to distinguish different types of pharmaceutical glasses.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab
Matrix-Assisted Laser Desorption Ionization (MALDI)

