Related Experiment Videos
Winter indoor air pollution in Alaska: identifying a myth
Maggie Isbell1, Mary Ellen Gordian, Lawrence Duffy
1Department of Chemistry and Biochemistry, and Institute of Arctic Biology, University of Alaska, Fairbanks 99775-6160, USA.
Abstract:
The benzene and toluene levels inside three homes with attached garages were measured for 12 consecutive weeks during the winter months in Fairbanks, Alaska (Latitude 64.5 degrees N). Results for air samples collected over 12 h for the homes showed indoor benzene mixing ratios ranging from 1.6 to 20.4 parts per billion of mixing ratio volume (ppbv), and toluene air mixing ratios ranging from 7.3 to 41.6 ppbv. A correlation between benzene and toluene levels in each home and similar regression lines suggested the same major emission source, car and small equipment gasoline, present in attached garages. In one home, there was a correlation between indoor benzene mixing ratios and the urinary biomarker, trans,trans-muconic acid. Inside, air mixing ratios of benzene and toluene decreased with decreasing outside temperature in all homes studied, even though homes were relatively tight to prevent heat loss during this period of low winter outdoor temperatures. It is suggested that buildup of these pollutants indoors is prevented by the influence of an increased indoor/outdoor temperature differential and an ensuing increase in home ventilation.