Related Experiment Video
Updated: Oct 2, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Evaluation of tube compensation in the Bennett 840 ventilator--a new ventilatory mode to support spontaneous
1Department of Intensive Care Medicine, Tohoku University Hospital, Sendai, Japan. k-hoshi@anes.med.tohoku.ac.jp
Abstract:
Respiratory care patients frequently require intubation with an endotracheal tube (ETT). Unfortunately, the ETT introduces a pressure drop (deltaPETT) that depends on the respiratory flow rate, thus increasing the work of breathing (WOB). Pressure support ventilation (PSV) cannot adequately compensate for this added WOB, because the degree of inspiratory assistance by PSV is fixed. Therefore, a technique called tube compensation (TC) has been developed to address deltaPETT. We examined the performance of TC and compared it with PSV of 5 cm H2O. The experimental system was constructed from a simulator, a test-lung, flow sensors, and a Bennett 840, and the respiratory parameters were studied. ETTs with IDs 6.5 and 8.0 mm were used. The quadratic approximation obtained for deltaPETT in the 6.5-mm ETT was 2.316 x flow + 7.910 x flow2, while that for the 8.0-mm ETT was 1.881 x flow + 3.353 x flow2. The maximum inspiratory flow (MIF) increased significantly with increasing TC, but tidal volume and inspiratory time did not show marked changes. The MIF for TC of 100% was larger than that for PSV of 5 cm H2O, when the 6.5-mm ID was used, but there was no significant difference between these modes when an ID of 8.0 mm was used. For both the 6.5 and 8.0-mm IDs, the PV loop corresponding to 100% TC was larger than that for PSV of 5 cm H2O. TC only compensated for the WOB caused by the ETT, whereas PSV compensated for the WOB caused by the ETT and the demand valve system. In clinical use, the differences between TC and PSV will demand attention.
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...