Related Experiment Video
Updated: Oct 2, 2026

High-definition Fourier Transform Infrared (FT-IR) Spectroscopic Imaging of Human Tissue Sections towards Improving Pathology
Published on: January 21, 2015
Transformation of metastable forms of acetaminophen studied by thermal Fourier transform infrared (FT-IR)
Shun-Li Wang1, Shan-Yang Lin, Yen-Shan Wei
1Biopharmaceutics Laboratory, Department of Medical Research & Education, Veterans General Hospital-Taipei, Shih-Pai, Taiwan, Republic of China.
Abstract:
A novel Fourier transform infrared (FT-IR) microspectroscopy equipped with a micro hot stage (thermal FT-IR microscopic system) was used to quickly study the phase transformation of acetaminophen polymorphs by a one-step process. Acetaminophen was sealed in KBr disc on the first and second heating processes under this system. The results indicate that the contour IR profile of form I acetaminophen in the first heating process changed dramatically only near 165 degrees C, but in the re-heating process exhibited a considerable alteration in peak intensity, band width and position near the temperatures at 85, 118 and 153 degrees C. A glassy form of acetaminophen was obtained after rapidly cooling the melted acetaminophen from 200 to 25 degrees C. The glassy acetaminophen was recrystallized at 85 degrees C to transform to the form III of acetaminophen in the reheating process, and then transformed to its form II near 118 degrees C. The thermal FT-IR microscopic system is a simple, quick and timesaving tool for investigation of the thermo-dependent molecular structure of acetaminophen polymorphs in the processes of recrystallization and polymorphic transition.
Related Concept Videos
IR Spectrometers
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
The ATR process begins by directing a beam...
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Frequency Region: Fingerprint Region
The...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
