Extracorporeal pressure monitoring and the detection of vascular access stenosis
W Kleinekofort1, M Kraemer, C Rode
1Fresenius Medical Care Deutschland GmbH, Research & Development, Bad Homburg, Germany. Wolfgang.Kleinekofort@fmc-ag.com
Abstract:
Prospective monitoring of static venous pressure is an established tool to detect outflow stenoses in a vascular access. However, with this method it is not possible to identify vascular stenoses which are localized between the arterial and venous dialysis needle. We describe a new approach based on both static arterial and venous extracorporeal pressures. Pressure data of 9 dialysis patients with normal vascular access function and 9 patients with stenotic access were analyzed. Extracorporeal pressure was found to depend on the position of the heart relative to the extracorporeal blood circuit. All patients with venous outflow stenoses had an elevated ratio of arterial and venous intra-access pressure to mean arterial pressure. In case of access stenosis between arterial and venous needle the ratio of venous pressure to mean arterial pressure was normal, and only the arterial pressure ratio was elevated. We conclude that combined arterial and venous intraaccess pressure measurement normalized by mean blood pressure detects venous stenosis as well as stenosis between the arterial and venous dialysis needle. To minimize the rate of access thrombosis both arterial and venous intra-access pressure should be monitored.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
06:29Wireless Telemetry Device Implantation in a Fontan Ovine Model for Continuous and Long-Term Hemodynamic Monitoring
Published on: May 2, 2025
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.