Related Experiment Video
Updated: Oct 2, 2026

Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Validity and reliability of three commercially available breath-by-breath respiratory systems
James Carter1, Asker E Jeukendrup
1Human Performance Laboratory, School of Sport and Exercise Sciences, The University of Birmingham, Edgbaston, B15 2TT, Birmingham, UK.
Abstract:
Information concerning the validity and reliability of commercial on-line gas analysis systems is limited. The aim of this study was to provide a comparison of the validity and reliability of three on-line systems (Oxycon Alpha, Oxycon Pro and Pulmolab EX670) with that of Douglas bags. Two separate studies were conducted. In study 1, the three gas analysis systems were compared with Douglas bags using a metabolic simulator over four increases in ventilation. In study 2, ten subjects were split into equal groups exercising at 100 W or 150 W for 85 min on three separate occasions. Each system was used twice per visit. Study 1 demonstrated that the Oxycon Alpha and Douglas bags produced similar respiratory values over all levels of ventilation. The Oxycon Pro tended to slightly overestimate mean expiratory flow (V(E) ), oxygen uptake ( VO2), carbon dioxide production (VCO2) and respiratory exchange ratio (RER) at the higher ventilations. The Pulmolab produced large overestimations at all ventilations for and RER (up to 26.3% away from expectations), whilst values for, and were slightly underestimated at higher ventilations (up to 7.5% from expectations). The results of study 2 support the findings of study 1, with the Oxycon Pro and Oxycon Alpha producing similar results compared to Douglas bags for, and RER. The coefficients of variation for and measured using Douglas bags, Oxycon Pro and Oxycon Alpha were 3.3-5.1%, 4.7-7.0% and 4.5-6.3%, respectively, whilst that for the Pulmolab was highly variable (26.8-45.8%). The exercise study showed the Oxycon Pro and Oxycon Alpha to be both valid and reliable on-line systems for the measurement of parameters of respiration, at least at workloads up to 150 W.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...

