Atmospheric pressure ionization LC-MS-MS determination of urushiol congeners
William M Draper1, Donald Wijekoon, Michael McKinney
1Sanitation and Radiation Laboratory Branch and Environmental Health Laboratory Branch, California Department of Health Services, Berkeley, California 94704, USA. wdraper@dhs.ca.gov
Abstract:
This paper describes atmospheric pressure ionization (API) LC-MS-MS determination of urushiols, 3-n-alkenyl- and -alkyl-substituted catechols responsible for poison oak dermatitis. Urushiol was isolated from Western poison oak according to the method of Elsohly et al. (1) (J. Nat. Prod. 1982, 45, 532-538)-the purified preparation contained C(17)- and C(15)-substituted urushiols with zero, one, two, and three double bonds as determined from GC-MS analysis of trimethylsilyl derivatives. Urushiol mixtures were separated on a C(18) reversed phase HPLC column with a methanol-water gradient with urushiols eluting in 100% methanol. Atmospheric pressure chemical ionization (APCI) produced primarily [M - H](-) and MH(+) molecule ions. Electrospray ionization (ESI) yielded [M - H](-) and adduct ions including [M + Cl](-). Daughter ions of [M - H](-) included quinoid radical anions ([M - H - H(2)](-) and m/z 122(-)) and a benzofuran phenate (m/z 135(-)). A suite of hydrocarbon fragments were produced by collision-induced dissociation of MH(+) directly or via an intermediate [MH - H(2)O](+) daughter ion. Six urushiol congeners, one not previously reported in poison oak, were determined by negative ion API-LC-MS-MS with detection limits of approximately 8 pg/microL (ESI) and approximately 800 pg/microL (APCI). API-LC-MS-MS was used to determine urushiol in surface wipes, air samples, and plant materials.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrum: Interpretation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences