Related Experiment Videos
Predictive value of short-wavelength automated perimetry: a 3-year follow-up study
Vicente Polo1, Jose M Larrosa, Isabel Pinilla
1Department of Ophthalmology, Miguel Servet University Hospital, P. Isabel La Católica, 50004 Zaragoza, Spain.
Purpose:
To determine whether structural changes in the retinal nerve fiber layer (RNFL) and functional abnormalities in short-wavelength automated perimetry (SWAP) can predict the onset of functional losses in standard automated perimetry patients suspected of having glaucoma.
Design:
Prospective observational case series.
Participants:
A total of 160 eyes of ocular hypertensive subjects (intraocular pressure greater than 21 mmHg and normal standard automated perimetry) were included in the study.
Interventions:
The subjects underwent RNFL photographic evaluation and SWAP. Standard automated perimetries were repeated after 3 years to evaluate glaucomatous losses.
Main Outcome Measures:
Onset of glaucomatous defects in conventional automated perimetry after 3 years of follow-up, with or without prior glaucomatous defects in RNFL and SWAP.
Results:
At the beginning of the study, 77 eyes showed RNFL losses (48%), and 58 eyes showed abnormalities in SWAP (36%). After the 3-year follow-up period, 14 of 77 eyes with RNFL losses had standard automated perimetry abnormalities (predicting sensitivity 93%), whereas 11 of 58 eyes with abnormal SWAP had standard automated perimetry losses (73% sensitivity).
Conclusions:
RNFL and SWAP losses are signs of early glaucomatous damage and can predict functional losses in standard automated perimetry.