Novel technique for stent delivery in tortuous coronary arteries: report of three cases
Valerian Fernandes1, Grzegorz L Kałuza, Boguslaw Godlewski
1The Methodist DeBakey Heart Center and Section of Cardiology, Department of Medicine, Baylor College of Medicine, Houston, Texas 77030, USA.
Abstract:
We present a novel technique for stent delivery across tortuous lesions. Gentle forward pressure was applied on the stent balloon while the balloon was inflated to 2-3 atm. This resulted in the balloon and stent crossing the impeding segment and settling in the target site where it was deployed with excellent angiographic outcome.