Gamma scintigraphic evaluation of a novel budesonide dry powder inhaler using a validated radiolabeling technique
Simon Warren1, Glyn Taylor, Jeffrey Smith
1Cardiff Scintigraphics Limited, Cardiff, United Kingdom.
Abstract:
A scintigraphic study was carried out to compare the lung deposition of budesonide delivered via Clickhaler and Turbuhaler dry powder inhalers in healthy volunteers. Validation of Technetium-99m ((99m)Tc) radiolabeling of the budesonide/lactose blend used in the Clickhaler and excipient-free budesonide used in the Turbuhaler was carried out using a multistage liquid impinger, and compared with reference unlabeled devices. Budesonide was quantified using high-performance liquid chromatography and (99m)Tc by scintillation counting. The percentages (SD) of fine particles (<5.5 microm diameter) from radiolabeled and unlabeled devices were not significantly different (p > 0.05). Mean values for drug and radiolabel, respectively, were 34.6% (2.5) and 31.6% (3.8) for the Clickhaler, and 29.8% (5.5) and 31.4% (5 6) for the Turbuhaler. Fifteen healthy male volunteers received a single dose (2 x 200 microg actuations) from both devices in a double-blinded, double dummy, crossover study. During dosing, each inhalation maneuver was recorded using a computer-linked pressure transducer. To permit accurate determination of radiolabeled drug deposition, the lung margins of each volunteer were determined by Krypton-81m ((81m)Kr) gas imaging. Mean [SD] lung deposition for the Clickhaler (26.8% [6.8], RSD 25.2) was significantly greater (p < 0.001) than for the Turbuhaler (15.8% [6.6], RSD 42.2). Inspiratory flow rate parameters were similar for both devices with peak and mean values of 73 and 51 L/min for the Clickhaler, and 73 and 47 L/min for the Turbuhaler, respectively. These results indicate that, in healthy volunteers, budesonide lung deposition was higher and more consistent with the Clickhaler than with the Turbuhaler.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

![Automated Preparation of [68Ga]Ga-3BP-3940 on a Synthesis Module for PET Imaging of the Tumor Microenvironment](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F68356.jpg&w=3840&q=50)