Use of disposable GRC electrodes for the detection of phenol and chlorophenols in liquid chromatography
Jiye Jin1, Toshiya Hiroi, Kiyohito Sato
1Instrumental Analysis Center, Gifu University, Japan.
Abstract:
In this study, a wall-jet flow cell with a GRC (graphite reinforced by carbon) electrode was designed for the amperometric detection of phenol and chlorophenols in liquid chromatography. The voltammetric responses of these analytes at the GRC electrodes are very similar to those at conventional glassy carbon electrodes. As the GRC electrodes were made of the same materials as commercially available mechanical pencil leads, they exhibit the advantages of low cost, simple surface renewability, lower residual current, and good electrode-to-electrode reproducibility, and thus can be used as disposable-type electrodes. Chromatographic separations of phenol, o-chlorophenol (o-CP), 2,4-dichlorophenol (2,4-DCP), 2,4,6-trichlorophenol (2,4,6-TCP), and pentachlorophenol (PCP) were achieved with an ODS column using a mobile phase containing a mixture of CH3CN and H20 (40:60) containing 25 mM L-(+)tartaric acid (pH = 4.5). Amperometric detections were based on the electrochemical oxidation of these compounds around +0.9 V vs. Ag/AgCl. Under the optimized conditions, linear calibrations were obtained in a range up to 100 microM for phenol, o-CP, 2,4-DCP, 2,4,6-TCP, and 200 microM for PCP, with the correlation coefficients r2 of 0.9992, 0.9997, 0.9986, 0.9992, and 0.9968, respectively. The chromatographic detection limits for the tested analytes were obtained at pmol levels.
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.