Related Experiment Video
Updated: Sep 30, 2026

Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
Published on: April 7, 2014
Quantitative phase-amplitude microscopy I: optical microscopy
E D Barone-Nugent1, A Barty, K A Nugent
1School of Botany, The University of Melbourne, Vic, 3010, Australia.
Abstract:
In this paper, the application of a new optical microscopy method (quantitative phase-amplitude microscopy) to biological imaging is explored, and the issue of resolution and image quality is examined. The paper begins by presenting a theoretical analysis of the method using the optical transfer function formalism of Streibl (1985). The effect of coherence on the formation of the phase image is explored, and it is shown that the resolution of the method is not compromised over that of a conventional bright-field image. It is shown that the signal-to-noise ratio of the phase recovery, however, does depend on the degree of coherence in the illumination. Streibl (1985) notes that partially coherent image formation is a non-linear process because of the intermingling of amplitude and phase information. The work presented here shows that the quantitative phase-amplitude microscopy method acts to linearize the image formation process, and that the phase and amplitude information is properly described using a transfer function analysis. The theoretical conclusions are tested experimentally using an optical microscope and the theoretical deductions are confirmed. Samples for microscopy influence both the phase and amplitude of the light wave and it is demonstrated that the new phase recovery method can separate the amplitude and phase information, something not possible using traditional phase microscopy. In the case of a coherent wave, knowledge of the phase and amplitude constitutes complete information that can be used to emulate other forms of microscopy. This capacity is demonstrated by recovering the phase of a sample and using the data to emulate a differential interference contrast image.
More Related Videos
08:39Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
07:38Multimodal Quantitative Phase Imaging with Digital Holographic Microscopy Accurately Assesses Intestinal Inflammation and Epithelial Wound Healing
Published on: September 13, 2016
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Atomic Force Microscopy
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
Overview of Microscopy Techniques