Is carbon dioxide as an insufflation agent for double contrast barium enema still worthwhile after a same-day
Takayuki Asao1, Kin-ichi Fujita, Jun-ichi Nakamura
1Department of Surgery I, Gunma University Faculty of Medicine, Maebashi, Japan. asaot@med.gunma-u.ac.jp
Purpose:
The aim of the study was to evaluate the efficacy of a double-contrast barium enema (DCBE) with CO(2) as a distending gas after a screening flexible sigmoidoscopy for reducing abdominal distension after an examination.
Patients And Methods:
A total of 165 DCBEs for patients with positive faecal occult blood tests were randomly allocated to a CO(2) group (n = 83) and a control group (n = 82) using air. Abdominal radiograph were taken before the DCBE, immediately following it, and 30 minutes later to determine residual bowel gas. The degree of abdominal discomfort was recorded using a scoring system.
Results:
The patients in the CO(2) group had significantly smaller amounts of residual gas 30 minutes after the DCBE than did the control group, both in the colon (P < 0.02) and in the small intestine (P < 0.001). There was significantly less abdominal distension after the DCBE in the CO(2) group compared to the control group (P < 0.001). The abdominal discomfort score at 30 minutes after CO(2) correlated with the residual gas in the small intestine (r = 0.390,P = 0.003) but not in the colon (r = 0.155, P = 0.15). The quality of the images and the number of polyps detected did not differ between two groups.
Conclusions:
We concluded that using CO(2) when administering a DCBE after a screening sigmoidoscopy was useful for relieving abdominal discomfort following the examination; furthermore, it did not impair the diagnostic ability of the DCBE.