Tensile strength of type IV dental stones dried in a microwave oven
Nur Hersek1, Senay Canay, Kivanç Akça
1Faculty of Dentistry, University of Hacettepe, Ankara, Turkey. nhersek@hotmail.com
Statement Of Problem:
It is known that drying dental stones in a microwave oven can save time, but the strength of the material may be affected by different drying methods.
Purpose:
This study evaluated the diametral tensile strength (DTS) of 5 type IV gypsum products at different time intervals using microwave and air-drying methods.
Material And Method:
. A total of 300 cylinder specimens were prepared from 5 type IV dental stones (Moldano, Amberok, Herastone, Shera-Sockel, and Fujirock; n = 60 per stone) in accordance with the manufacturers' recommendations. Half of the specimens of each stone (n = 30) were dried in open air within a temperature range of 20 +/- 2 degrees C; the other half (n = 30) underwent initial setting in a silicone rubber mold in open air for 10 minutes and then were dried in a microwave oven for 10 minutes. Within these groups, 10 specimens were tested under diametral compression at each of the following time periods: 30, 60, and 120 minutes after drying. Three-way analysis of variance and Scheffe's post hoc test were performed for statistical comparisons at a significance level of P<.05.
Results:
At all time intervals, the diametral tensile strength values for dental stones dried in a microwave oven (mean 2.99 MPa) were significantly higher (P<.01) than the values for specimens dried in open air (mean 2.53 MPa).
Conclusion:
Within the limitations of this study, microwave oven drying had a positive effect on the diametral tensile strength of 5 type IV dental stones.
Related Concept Videos
Brick Durability, Strength, and Appearance
Mortar Properties
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen also...
Bonding and Strength of Aggregate