Related Experiment Video
Updated: Sep 30, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Evaluation of a new ultrasound contrast agent (AI-700) using two-dimensional and three-dimensional imaging during
Jiefen Yao1, Masaaki Takeuchi, Claudius Teupe
1Cardiovascular Imaging and Hemodynamic Laboratory Division of Cardiology, Department of Medicine, New England Medical Center, Tufts University School of Medicine, Boston, USA.
Background:
A new intravenous contrast agent, AI-700, was evaluated to determine whether a bolus injection could be used to detect myocardial perfusion abnormalities during acute ischemia by using 2-dimensional (2D) and 3-dimensional (3D) myocardial contrast echocardiography.
Methods:
2D MCE was performed in 14 closed-chest dogs during coronary occlusion by using both continuous and triggered gray scale harmonic imaging and triggered power Doppler imaging. 3D MCE (open-chest) and nuclear perfusion imaging were performed in 10 of the 14 dogs. Postmortem triphenyl tetrazolium chloride (TTC) staining was performed to verify infarction.
Results:
Thirteen of the 14 dogs had infarct by TTC; all 10 that had nuclear imaging showed a perfusion defect. Of the 13 dogs that had infarction, perfusion defects were detected in all (13 of 13) by gray scale harmonic imaging (sensitivity = 100%), and in 11 of 13 by power Doppler imaging (sensitivity = 85%). All 10 dogs that had nuclear imaging showed perfusion defects by gray scale harmonic imaging (sensitivity = 100%) and 8 of 10 by power Doppler imaging (sensitivity = 80%). The perfusion defect size, derived from 3D imaging (25% +/- 12%) correlated well with that from nuclear imaging (24% +/- 12%) (y = 0.9x + 3.8, r = 0.96, mean difference = 1.3% +/- 2.6%). The perfusion defect mass by 3D (22 +/- 14 g) also correlated well with the infarct mass by TTC staining (24 +/- 16 g) (y = 0.8x + 2.9, r = 0.89, P <.001, mean difference = -2.8 +/- 7.6 g).
Conclusion:
After a single bolus of AI-700, both 2D and 3D MCE could accurately detect perfusion defects representing the area at risk of infarction during acute ischemia compared with nuclear imaging and predicted the size of infarction as verified by TTC staining.
More Related Videos
09:56Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
Published on: November 4, 2014
06:45Integrated Photoacoustic, Ultrasound, and Angiographic Tomography (PAUSAT) for NonInvasive Whole-Brain Imaging of Ischemic Stroke
Published on: June 2, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System IV: CMRI
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging