Synchronous Triplanar Reconstruction Integrated with Color Doppler Mapping for Precise and Rapid Localization of Thyroid Lesions
Published on: February 9, 2024
Exploratory thyroid ultrasound-computed tomography synthesis using anatomy-preserving contrastive unpaired
Enhui He1, Yiran Wang2, Zhanxiong Yi1
1Department of Ultrasound, Beijing Friendship Hospital, Beijing, China.
Objectives:
When ultrasound (US) and computed tomography (CT) are both clinically indicated, unpaired image translation may support model development but cannot replace either examination. We evaluated Anatomy-Preserving Contrastive Unpaired Translation (AP-CUT), a CUT-based framework with a CT-source Sobel edge-consistency term for CT → US translation.
Methods:
The study used 832 malignant thyroid US images from TN5000 and 800 cervical CT slices from Head-Neck-CHUM. CycleGAN, CUT, and AP-CUT were compared with a low-dimensional Fréchet proxy and nearest-neighbor SSIM/PSNR. Bounding boxes were used only to prepare local US regions for qualitative US → CT examples. A separate single-run experiment treated 600 CT → US outputs as malignant-class training examples and evaluated three classifiers.
Results:
AP-CUT had the highest CT → US nearest-neighbor SSIM (0.1388), compared with 0.0982 for CUT and 0.1247 for CycleGAN. CycleGAN had the lowest US → CT proxy FID (10.4; lower is better). In the classification experiment, the absolute AUC change was +0.0002 for ResNet-50, +0.0261 for EfficientNet-B4 (0.7297 to 0.7558), and -0.0109 for EfficientNet-B4 + CBAM.
Conclusions:
The CT-source regularizer improved one relative structural proxy over CUT, but absolute structural scores remained low. US → CT outputs are local CT-domain-styled patches rather than reconstructed axial CT images, and the mixed single-run classification results do not establish clinical utility.