Bacterial contamination of propofol: the effects of temperature and lidocaine
1Adnan Menderes University, Department of Anaesthesiology and Reanimation, Aydin, Turkey. onaydin@superonline.com
Background And Objective:
The intravenous anaesthetic propofol may become contaminated once the ampoules have been opened. The effect of lidocaine and cooling was tested on the bacterial contamination of propofol.
Methods:
The study was performed in two parts. In Part 1,1920 aliquots of propofol alone, and of a propofollidocaine mixture, were drawn into sterile syringes and stored at room temperature (24-26 degrees C) or in the refrigerator (12-14 degrees C). In Part 2, 1200 aliquots from opened ampoules of propofol alone, or as a propofol-lidocaine mixture, were stored at room temperature or in the refrigerator. Samples were aerobically cultured at 0, 1, 2, 4, 8 and 12 h.
Results:
In Part 1, diphtheroid bacillus was isolated from one aliquot (0.06%). In Part 2, there was bacterial growth in both groups; the number of contaminated ampoules increased with time and it was 20-26% at 12 h. Diphtheroid bacilli and coagulase-negative staphylococci were the most frequent micro-organisms.
Conclusions:
When propofol is stored in opened ampoules, the bacterial contamination rate is high. Adding lidocaine, or storing opened ampoules at 12-14 degrees C, does not affect the contamination rate, except during the first few hours. It is advisable to draw propofol aseptically into a syringe in an amount that can be used during one procedure.
Insights
Bacterial contamination of opened propofol ampoules is high. Adding lidocaine or refrigeration does not significantly reduce contamination, emphasizing aseptic technique for single-procedure use.
Area of Science:
- Anesthesiology
- Microbiology
- Pharmaceutical Science
Background:
- Intravenous anesthetic propofol can become contaminated after ampoule opening.
- Bacterial contamination poses a risk to patient safety during anesthesia administration.
Purpose of the Study:
- To evaluate the impact of lidocaine and cooling on bacterial contamination of propofol.
- To determine optimal storage conditions for opened propofol ampoules.
Main Methods:
- Two-part study involving propofol and propofol-lidocaine mixtures.
- Aliquots stored at room temperature or refrigerated, with samples cultured over 12 hours.
Main Results:
- Bacterial growth observed in opened propofol ampoules, increasing over time.
- Contamination rates reached 20-26% at 12 hours.
- Diphtheroid bacilli and coagulase-negative staphylococci were the most common contaminants.
Conclusions:
- Opened propofol ampoules exhibit a high rate of bacterial contamination.
- Lidocaine addition and refrigeration showed minimal impact on contamination rates beyond initial hours.
- Aseptic technique, drawing only the needed amount for a single procedure, is crucial.
Related Concept Videos
Parenteral Anesthetics: Overview
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...
Local Anesthetics: Common Agents and Their Applications
Cocaine is an ester of benzoic acid and methylecgogine. It is used to anesthetize and vasoconstrict locally. Currently, it is used primarily for topical applications. It is beneficial for surgeries on the upper respiratory tract, providing anesthesia and shrinking the mucosa. Cocaine in the form of cocaine hydrochloride is...
Inhalational Anesthetics: Overview
Local Anesthetics: Pharmacokinetics
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia