Direct conversion detectors: the effect of incomplete charge collection on detective quantum efficiency
Related Experiment Video
Updated: Sep 30, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
James G Mainprize1, Dylan C Hunt, Martin J Yaffe
1Department of Medical Biophysics, University of Toronto, Sunnybrook & Women's College Health Sciences Centre, Ontario, Canada. mprize@sten.sunnybrook.utoronto.ca
Abstract:
Direct conversion detectors offer the potential for very high resolution and high quantum efficiency for x-ray imaging, however, variations in signal can arise due to incomplete charge collection. A charge transport model was developed to describe the signal and noise resulting from incomplete charge collection. This signal to noise ratio (SNR) reduction was incorporated into the cascaded systems model for a simple x-ray detector. A new excess noise factor, A(c) (termed the collection noise factor) is introduced to describe the reduction in detective quantum efficiency (DQE). The DQE is proportional to the product of the quantum efficiency and the collection noise factor. If the trapping cross sections for electrons and holes are very different, and if the detector is biased improperly, the collection noise factor can drop to as low as 50%. In addition, the signal loss due to incomplete charge collection will reduce the DQE in the presence of added noise. Because of this, the DQE generally does not continue to improve with greater detector thickness. The collection noise factor and DQE are predicted for CdZnTe, PbI2, and Se. The optimization of detector thickness should be based not only on quantum efficiency but also on the charge collection statistics, which are influenced by bias field and polarity.
More Related Videos
Related Concept Videos
Determination of Crystal Structures
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Analyzers: Common Types