Related Experiment Video
Updated: Sep 30, 2026

Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
Published on: October 6, 2023
Evaluation of patient exposure in computerised tomogram in Poland
1The Nofer Institute of Occupational Medicine, Department of Radiation Protection, Lodz, Poland. mastan@imp.lodz.pl
Abstract:
The increasing number of computerised tomography (CT) procedures performed in Poland in recent years has resulted in a growing contribution of these examinations to the whole exposure of the population to ionising radiation from medical sources. (The number of CT examinations in Poland was 170,000 in 1995 and 460,000 in 1999.) An evaluation is presented of doses to patients in CT examinations performed with different types of CT unit. To evaluate the exposure to patients dose linear product (DLP) was measured using a NOMEX dosemeter with a pencil chamber (PTW, Frieburg) and the cylindrical PMMA phantoms 'head' and 'body'. CTDI values were evaluated according to current methodology as described in European Guidelines (EUR 16262). The measurements were performed for seven types of CT unit made by different companies. The CTDI values were also compared to reference levels recommended by IAEA. In conclusion it was found that the value of collective effective dose (2200 man.Sv), has increased in Poland nearly 4 times in comparison to 1995, whereas the number of CT examinations increased nearly 3 times in this period. For most of the 'controlled' CT scanners the values of CTDI in head procedures are near to or higher than the IAEA Reference Level (50 mGy); this can result from the protocols, which are chosen without a dose analysis.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET