Evaluation of doses to patients in X-ray diagnostics in Poland
1Department of Radiological Protection, Nofer Institute of Occupational Medicine, Lódź, Poland.
Abstract:
The study includes a detailed analysis of patients' exposure to ionising radiation resulting from diagnostic radiology in Poland. Data concerning the number and types of examinations were collected by wide-range questionnaire surveys conducted in 1986 and 1995. As the result, the number of examinations per 1000 inhabitants was found to be 572 in 1986 and 715 in 1995. Most of the examinations were the basic, conventional ones (mostly chest and spine radiography). A great part of this study includes detailed description of the methodology of evaluating doses received by patients from X-ray procedures. The theoretical Monte Carlo simulation with the original author's computer code was used for this purpose. As the result, the doses to patients in six age groups (< 1, 1-4, 5-9, 10-14, 15-19 and the adults) were estimated. In simulation process the examined persons were represented by the appropriate mathematical human phantoms. The doses from particular examinations performed in exposure conditions routinely used in Polish radiology departments are presented. The mean effective doses for adult patients from typical examinations are: 0.11 mSv from chest, 3.0 mSv from thoracic spine, and 4.3 mSv from L-S spine radiography. Significantly higher doses were received by patients undergoing fluoroscopy procedures: 23 mSv from barium enema and 14 mSv from the stomach examination. In conclusion, the estimated exposure levels in Poland are as follows: the average effective dose per examination: (1.4 +/- 0.6) mSv in 1986, (1.2 +/- 0.5) mSv in 1995, the average effective dose per capita: (0.8 +/- 0.3) mSv in 1986 and 1995.
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography