Purpose:
The goal of this study was to evaluate curing-dependent changes in color and translucency parameter (TP) values of composite bleach shades.
Materials And Methods:
Thirty bleach shades of microhybrid and microfill composites were analyzed. Specimens (n = 5) were made as disks, 10 mm in diameter and 2 mm thick, using cylindrical molds. Specimens were polymerized for 60 seconds using a light-curing unit. Data were collected before and after composite curing using a spectrophotometer and analyzed using the appropriate color-difference metric equations.
Results:
L*a*b* ranges (maximum minus minimum values) for microhybrids were 17.7, 2.91, and 7.97, respectively. Corresponding ranges for microfills were 14.4, 1.26, and 4.27, respectively. Curing-dependent color differences varied from 3.7 to 12.0 deltaE* units, whereas TP values of cured resin composites varied from 2.0 to 7.1. Light-curing caused increase of microhybrid TP values (+0.7) and decrease of microfill TP values (-0.7). Color differences were found to be acceptable for five of six composite pairs of the same shade designation (each of them made by the same manufacturer) in post-curing measurements against white background.
Clinical Significance:
Curing-dependent color and TP changes indicate that dentists should use cured composite for matching of shade and translucency. Tested materials became less saturated, with microhybrids becoming darker and microfills becoming lighter after polymerization. Light-curing caused an increase in translucency of microhybrids and a reduced translucency in microfills.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...