Related Experiment Video
Updated: Aug 2, 2026

Accumulation and Analysis of Cuprous Ions in a Copper Sulfate Plating Solution
Published on: March 20, 2019
A simple and very sensitive spectrophotometric method for the direct determination of copper ions
Juan J Pinto1, Carlos Moreno, Manuel García-Vargas
1Department of Analytical Chemistry, Faculty of Marine and Environmental Sciences, University of Cádiz, 11510 Puerto Real, Spain.
Abstract:
A sensitive spectrophotometric method for the direct determination of copper in aqueous samples without a preconcentration step has been developed. It is based on the formation of a yellow complex with the chromogenic reagent di-2-pyridyl ketone benzoylhydrazone (dPKBH) in an alkaline medium. The complex stoichiometry was 1:2 (Cu:dPKBH) and presents maximum absorbance at 370 nm. The influence of chemical variables affecting the behaviour of the system such as pH, concentration of dPKBH, buffer solution and ethanol, order of addition of the reagents and stability of the complex, were evaluated. The molar absorptivity (epsilon) was 3.92x10(4) L mol(-1) cm(-1), and Beer's law was obeyed up to 3 mg L(-1) of copper. The relative standard deviation was 0.46% (n=11) for a sample containing 1 mg L(-1) Cu(II). The limit of detection was 2.5 micro g L(-1) and was therefore more sensitive than the direct methods reported previously. Finally, the method was successfully validated by analysing several real samples with different matrices, such as tap water, natural water or copper alloys, with an average relative error of 2.46%.
Related Concept Videos
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation and Co-precipitation
Extraction: Advanced Methods
EDTA: Indirect and Alkalimetric Titration