Methodology for Sputum Induction and Laboratory Processing
Published on: December 17, 2017
Comparison of sputum induction using high-output and low-output ultrasonic nebulizers in normal subjects and patients
Martin G Kelly1, Vanessa Brown, S Lorraine Martin
1Department of Respiratory Medicine, Belfast City Hospital, Northern Ireland. m.g.kelly@qub.ac.uk
Study Objective:
s: Induced sputum is used to investigate pulmonary diseases. Low-output ultrasonic nebulizers have become available and have potential advantages over high-output nebulizers. We hypothesized that a low-output nebulizer would give comparable results to a high-output nebulizer, with an acceptable safety profile.
Design:
Randomized, crossover study.
Setting:
University teaching hospital.
Participants:
Ten normal subjects and 10 patients with COPD.
Interventions:
Participants attended for sputum induction on two occasions in random order using low-output and high-output nebulizers.
Measurements And Results:
Lung function and oxygen saturation were measured during sputum induction, and tolerability of the procedure was assessed. Cell counts, interleukin 8, and neutrophil elastase were measured in sputum. Use of the high-output nebulizer resulted in a greater FEV(1) (mean +/- SEM, 0.29 +/- 0.04 L vs 0.21 +/- 0.04 L; p = 0.04) and percentage drop in FEV(1) (25.8 +/- 2.6% vs 19.5 +/- 2.9%, respectively; p = 0.02) compared with the low-output nebulizer in patients with COPD. There was a shorter tolerated nebulization time with the high-output nebulizer compared with the low-output nebulizer: 12.7 +/- 2.0 min vs 16.5 +/- 1.8 min, respectively (p = 0.02). Modified Borg scores were lower with the low-output nebulizer than the high-output nebulizer in normal subjects: median, 0 (interquartile range [IQR], 0 to 1) vs median, 1.5 (IQR, 0 to 2), respectively (p = 0.05). There were no differences in cell counts and soluble markers of inflammation.
Conclusions:
The low-output ultrasonic nebulizer is comparable to high-output nebulizer for cellular and soluble markers of inflammation, results in a smaller reduction in FEV(1), is better tolerated, and is a suitable tool for investigating airway inflammation in patients with COPD.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Inhaled Medications
Sputum Studies II: Culture and Sensitivity
Sputum culture and sensitivity is a medical procedure used to diagnose bacterial infections in the respiratory tract and select the most appropriate antibiotics for treatment. This process involves analyzing sputum samples of thick and opaque secretions produced in the lungs and airways. These samples are collected from patients and then sent to the laboratory for analysis.
The test can identify various pathogens responsible for respiratory infections, including Streptococcus,...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-I: Introduction