A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Simultaneous iterative reconstruction of emission and attenuation images in positron emission tomography from
M Landmann1, S N Reske, G Glatting
1Abteilung Nuklearmedizin, Universität Ulm, Germany.
Abstract:
For quantitative image reconstruction in positron emission tomography attenuation correction is mandatory. In case that no data are available for the calculation of the attenuation correction factors one can try to determine them from the emission data alone. However, it is not clear if the information content is sufficient to yield an adequate attenuation correction together with a satisfactory activity distribution. Therefore, we determined the log likelihood distribution for a thorax phantom depending on the choice of attenuation and activity pixel values to measure the crosstalk between both. In addition an iterative image reconstruction (one-dimensional Newton-type algorithm with a maximum likelihood estimator), which simultaneously reconstructs the images of the activity distribution and the attenuation coefficients is used to demonstrate the problems and possibilities of such a reconstruction. As result we show that for a change of the log likelihood in the range of statistical noise, the associated change in the activity value of a structure is between 6% and 263%. In addition, we show that it is not possible to choose the best maximum on the basis of the log likelihood when a regularization is used, because the coupling between different structures mediated by the (smoothing) regularization prevents an adequate solution due to crosstalk. We conclude that taking into account the attenuation information in the emission data improves the performance of image reconstruction with respect to the bias of the activities, however, the reconstruction still is not quantitative.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...